Ceiling PIR Motion Sensor 360 Degree with Wide Range

Product Details
Customization: Available
Function Type: Infrared Range and Communication System
Detection Type: Heat Detectors
Still deciding? Get samples of US$ 2.5/Piece
Request Sample
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015
  • Ceiling PIR Motion Sensor 360 Degree with Wide Range
  • Ceiling PIR Motion Sensor 360 Degree with Wide Range
  • Ceiling PIR Motion Sensor 360 Degree with Wide Range
  • Ceiling PIR Motion Sensor 360 Degree with Wide Range
  • Ceiling PIR Motion Sensor 360 Degree with Wide Range
Find Similar Products

Basic Info.

Model NO.
ES-P36A
Output Signal Type
PIR
Production Process
Injection
Material
PC
IP Rating
IP20
Certification
CE
Customized
Customized
Transport Package
by Sea/Air
Specification
50pc/carton
Trademark
E. S. P.
Origin
China
HS Code
8531901000
Production Capacity
600000PCS/Month

Product Description

UFO 360 degree ceiling mount Infrared Motion Sensor
Model ES-P36B 
Power source 220~240V/AC 110-130V/AC 50/60HZ
Detection Degree  360°
Waterproof grade IP20
Working temperature   -20ºC~+40ºC
Rated load 800w for incandescent lamp
400w for led lamp
Ambient Light  <10Lux~2000Lux adjustable 
Time setting  10sec~7min adjustable 
Package: white box/color box per piece; blister card;
with instruction/ inner box and outer carton

Welcome to use ES-P36A Infrared Motion Sensor!

The product adopts good sensitivity detector and integrated circuit. It gathers automatism, convenience, safety, saving-energy and practical functions. It utilizes the infrared energy from human as control-signal source and it can start the load at once when one enters detection field. It can identify day and night automatically. It is easy to install and used widely.
 

SPECIFICATION:

Power Source: 220-240V/AC                             Detection Range: 360°

Power Frequency: 50/60Hz                               Detection Distance: 6m max(<24ºC)

Ambient Light: <10-2000LUX (adjustable)        Working Temperature: -20~+40ºC

Time Delay: Min.10sec±3sec                            Working Humidity: <93%RH

           Max.7min±2min                                      Power Consumption: approx 0.5W

Rated Load: Max.800WIncandscent lamp         Installation Height: 2.2-4m

            400W Energy saving lamp +LED          Detection Moving Speed: 0.6-1.5m/s

FUNCTION:

Ø Can identify day and night: The consumer can adjust working state in different ambient light. It can work in the daytime and at night when it is adjusted on the(+) position (max). It can work in the ambient light less than 10LUX when it is adjusted on the (-) position (min). As for the adjustment pattern, please refer to the testing pattern. 

Ø Time-Delay is added continually: When it receives the second induction signals within the first induction, it will restart to time from the moment.

INSTALLATION ADVICE:

As the detector responds to changes in temperature, avoid the following situations:

Ø Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.

Ø Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.

Ø Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
 

TEST: 

Ø Turn the TIME knob anti-clockwise on the minimum (-)(10s).Turn the LUX knob clockwise on the maximum. (+) (sun).

Ø Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on. While there is no another induction signal any more, the load should stop working within 10sec±3sec and the lamp would turn off.

Ø Turn LUX knob anti-clockwise on the minimum (-). If the ambient light is more than 10LUX, the sensor would not work and the lamp stop working too. If the ambient light is less than 10LUX (darkness), the sensor would work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.

Note: when testing in daylight, please turn LUX knob to (+)   (SUN) position, otherwise the sensor lamp could not work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.

SOME PROBLEM AND SOLVED WAY:

Ø The load does not work:

a. Please check if the connection of power source and load is correct.

b. Please check if the load is good.

c. Please check if the settings of working light correspond to ambient light.

Ø The sensitivity is poor:

a. Please check if there is any hindrance in front of the detector to affect it to receive the signals.

b. Please check if the ambient temperature is too high.

c. Please check if the induction signal source is in the detection field.

d. Please check if the installation height corresponds to the height required in the instruction.

e. Please check if the moving orientation is correct.

Ø The sensor can not shut off the load automatically:

a. Please check if there is continual signal in the detection field.

b. Please check if the time delay is set to the maximum position.

c. Please check if the power corresponds to the instruction.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier